当前位置:主页 > 产品展示 > 西门子传感器 >

西门子SIEMENS风管温湿度传感器 型号概览

作者:admin | 来源:未知 | 发布时间:2016-08-10 16:48

西门子SIEMENS风管温湿度传感器 型号概览简介:
 风管温湿度传感器

1. 应用领域
       ♦ 通过测量环境的相对湿度和温度,调节空气,从而提高人体的舒适感。
       ♦控制送风与排风
       ♦参考传感器,如露点转换
       ♦限定传感器,如与蒸汽湿度传感器相连、测量值显示与一个楼宇自控系统相连
       ♦焓值与绝对湿度传感器

2.产品特点
   ♦在滞后性、长期稳定性和可重复性方面具有突出的优点
   ♦ 可以提供单一湿度信号的湿度传感器或者与温度传感器组合的温湿度传感器
   ♦覆盖风道和房间测量应用
   ♦高精度

西门子SIEMENS风管温湿度传感器 型号概览参数:
技术参数:

型号 材质/信号 测量范围 精度 响应时间 防护等级 电源 接线 备注
温度 湿度 温度 湿度 温度 湿度 温度 湿度
QFM1660 0-10V 0-10V 0...50?C   25?C:±0.8?C 10...90%:±5% IP42 AC24V 5线  
QFM2100 0-10V 0...50?C;
-35...35?C;
-40...70?C;
10...90% 30...70%:±3%
0...95%:±5%
<20s IP54 AC/
DC24V
3线  
QFM2101 4-20mA 0...50?C;
-35...35?C;
-40...70?C;
0...95% 30...70%:±3%
0...95%:±5%
<20s IP54 DC24V 2线  
QFM2120 Ni1000 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...95% 13...35?C:±0.8K;
-35...50?C:±1.0K
30...70%:±3%
0...95%:±5%
3.5min <20s IP54 AC/
DC24V
4线  
QFM2140 T1(PTC) 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...95% 13...35?C:±0.8K;
-35...50?C:±1.0K
30...70%:±3%
0...95%:±5%
3.5min <20s IP54 AC/
DC24V
4线  
QFM2160 0-10V 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...95% 13...35?C:±0.8K;
-35...50?C:±1.0K
30...70%:±3%
0...95%:±5%
3.5min <20s IP54 AC/
DC24V
4线  
QFM2171 4-20mA 4-20mA 0...50?C;
-35...35?C;
-40...70?C;
0...95% 13...35?C:±0.8K;
-35...50?C:±1.0K
30...70%:±3%
0...95%:±5%
3.5min <20s IP54 DC24V 4线  
QFM3100 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...100% ±2%
 
/ <20s IP65 AC/
DC24V
2线  
QFM3101 4-20mA 0...50?C;
-35...35?C;
-40...70?C;
0...100% ±2% / <20s IP65 DC24V 3线  
QFM3160 0-10V 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...100% 15...35?C:±0.6K;
-35...70?C:±0.8K
±2% / <20s IP65 AC/
DC24V
4线  
QFM3160D 0-10V 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...100% 15...35?C:±0.6K;
-35...70?C:±0.8K
±2% / <20s IP65 AC/
DC24V
4线 带液晶显示
QFM3171 4-20mA 4-20mA 0...50?C;
-35...35?C;
-40...70?C;
0...100% 15...35?C:±0.6K;
-35...70?C:±0.8K
±2% / <20s IP65 DC24V 4线  
QFM3170D 4-20mA 4-20mA 0...50?C;
-35...35?C;
-40...70?C;
0...100% 15...35?C:±0.6K;
-35...70?C:±0.8K
±2% / <20s IP65 DC24V 4线 带液晶显示
QFM4160 0-10V 0-10V 0...50?C;
-35...35?C;
-40...70?C;
0...100% 15...35?C:±0.6K;
-35...70?C:±0.8K
±2% / <20s IP65 AC/
DC24V
4线 带标定证书
QFM4171 4-20mA 4-20mA 0...50?C;
-35...35?C;
-40...70?C;
0...100% 15...35?C:±0.6K;
-35...70?C:±0.8K
±2% / <20s IP65 DC24V 4线 带标定证书
 

西门子SIEMENS风管温湿度传感器 型号概览型号:

安装注意事项

湿度传感器会受到空气流速的影响,传感器附近的空气流动速度不应大于10m/s
注意:安装传感器时应采用穿孔的保护罩或者盖子(例如钢制保护套管)
避免安装在流动死区(如果没有气流,可能引起过饱和状态) 如果传感器安装在负压管道内,气体可能从外部抽进设备以及安装孔。
(为了防止读数不准,应当有效密封)
每一个湿度传感器的下游方向都是应该有一个测试孔
推荐直径:40mm

QQ交谈留言反馈